Features

Capability by capability, with the limit on each.

Chassira's features are the mechanics of a system that is allowed to touch production equipment: typed runs, a policy engine, locked parameters, named approvals, fused inspection, a twin, the as-built record and an audit log. The list below is design scope, not a shipped feature list.

12 capabilitiesPolicy-checked writesAppend-only audit

run_41a9c2 · agent graph · plant BIW-2 · scenario 10 nodes · 1 approval gate
01 · orchestrator ingest.shift ✓ SUCCEEDED 02 · vehicle_line twin.simulate ✓ SUCCEEDED 03 · stamp_form stamp.form ✓ SUCCEEDED 04 · orchestrator approve.human ◆ APPROVAL 05 · weld_join weld.join ✓ SUCCEEDED 06 · frame_geometry frame.geometry ✓ SUCCEEDED 07 · paint_finish paint.finish ✓ SUCCEEDED 08 · powertrain_battery marriage.torque ✓ SUCCEEDED 09 · quality_anomaly inspect.fuse ✓ SUCCEEDED 10 · eol_calibrate eol.release ✓ SUCCEEDED

Illustrative scenario: Plant BIW-2 · EV crossover body shop to end of line · shift 1, one approval gate

Features

What the platform does

Each capability names what it does and where its limit sits.

Runs

Typed, ordered, inspectable

A run is a goal, a plan and a graph of typed steps. Every step has an agent, a tool, a duration and a status, and the whole record is kept per body and vehicle.

Policy engine

Limits enforced at call time

Tag allow-lists, per-tag rate and magnitude limits, the qualified envelope, autonomy level, shift, program and interlock state are evaluated before any setpoint moves. NeMo Guardrails enforces spec, IATF, functional-safety and approval policy.

Locked parameters

Some things are never writable

Torque specifications, battery-joint parameters and end-of-line test limits and verdicts are read-only to every agent. Weld schedules wait for a named engineer until the joint family is qualified.

Approvals

Named humans at the gate

Weld-schedule changes, torque-related decisions and vehicle release wait for the approver the plant names. The request, the evidence and the decision are logged.

Fused inspection

Vision, traces, measurement, tests

Gap-and-flush and paint-defect vision, weld and torque traces, in-line metrology and test results fused into one build-quality model per vehicle, localised to station, robot, tool and body.

Plant twin

Rehearse before the shift

Candidate weld sequences, framing offsets, booth windows and line balances ranked on geometry, defect map, expulsion risk and takt before a setpoint moves.

As-built record

The record of every vehicle

Welds, measurements, paint readings, torque traces, test results, approvals, rework and disposition, exportable for launch, IATF, APQP and warranty review.

Review console

Approve, correct, feed back

Process and quality engineers see recommendations with their evidence, approve or correct them, and those corrections train the models.

Audit log

Append-only, exportable

Every agent action with source evidence, the approved envelope, confidence, predicted quality, rework, downtime and warranty impact, rollback path, approver and vehicle scope.

Standards-cited reasoning

Every answer cites its source

Retrieval over weld, paint and torque specs, APQP and PPAP control plans, IATF 16949, ISO 26262-aware requirements and recall procedures, tenant-isolated.

Process memory

The launch engineer's craft, written down

Per-plant and per-program build-quality history and per-station and per-robot performance memory, versioned and scoped per tenant.

Synthetic rare events

Hard cases, validated

Rare weld defects, paint failures, geometry-drift modes, occluded joints and misbuild cases generated with Cosmos and Omniverse Replicator and validated against real distributions before promotion. Planned.

Run timeline · scenario

One scenario shift, step by step

Every Chassira run is an ordered, inspectable sequence. This is run_41a9c2 on Plant BIW-2 · EV crossover body shop to end of line · shift 1. Scenario completes in 10 steps with one approval gate. Weld schedule change on robot W-14 approved by the body-shop launch engineer, framing offset held inside the envelope, booth humidity trimmed before the predicted dirt defects appeared, one pack held at marriage on a torque trace, and the shift released with full as-built records.

run_41a9c2 Plant BIW-2 · EV crossover body shop to end of line · shift 1 illustrative scenario SUCCEEDED
  1. 01 ingest.shift SUCCEEDED 0.8 s

    Plant Orchestrator · Pulled the shift build sequence, program control plan and qualified envelopes from MES: 412 bodies, four trim variants, weld schedule set W-rev 7, framing targets per station, paint colour blocks, torque specifications. Locked every safety-critical parameter as read-only.

  2. 02 twin.simulate SUCCEEDED 1 m 40 s

    Vehicle-and-Line Twin · Simulated 18 candidate weld-sequence, framing-offset and booth-window combinations on the plant twin, ranked on predicted body geometry, expulsion risk at robot W-14, paint defect map and takt against launch cadence.

  3. 03 stamp.form SUCCEEDED continuous

    Stamp-and-Form · Blank feed on press line P-3 adjusted by 0.4 mm and lubricant dose raised 3 percent for the new coil lot as springback risk on the rear door inner climbed. Panel dimension held inside the window; genealogy handed to framing.

  4. 04 approve.human APPROVAL 3 m 12 s

    Plant Orchestrator · Candidate #6 lowers weld current 2 percent and adds 20 ms hold on robot W-14 to cut predicted expulsion. Weld schedules are crash-safety critical and stay with a human, so the change was held for the body-shop launch engineer and approved at 06:14:52.

  5. 05 weld.join SUCCEEDED continuous

    Weld-and-Join · Approved schedule 7b applied on W-14. Current and force traces confirmed inside the window on the first 40 bodies; predicted expulsion risk fell from 0.31 to 0.06 and no geometry debt was introduced at the adjacent seams.

  6. 06 frame.geometry SUCCEEDED continuous

    Frame-and-Geometry · Framing station FS-1 offset corrected by 0.3 mm on the left B-pillar datum inside the qualified envelope as in-line measurement trended toward the tolerance edge. Gap-and-flush vision confirmed the correction on the next 25 bodies.

  7. 07 paint.finish SUCCEEDED continuous

    Paint-and-Finish · Booth B-2 humidity trimmed 2 points and airflow rebalanced for the dark-colour block as the defect model predicted dirt on horizontal panels. Film build held inside the window on the first colour block.

  8. 08 marriage.torque SUCCEEDED continuous

    Powertrain-and-Battery · Pack PK-1182 held at marriage after a torque-to-yield trace on fastener 7 fell outside the specification curve. Routed to rework with the trace attached; torque specification untouched, as always.

  9. 09 inspect.fuse SUCCEEDED continuous

    Quality-and-Anomaly · Gap-and-flush and paint-defect cameras, weld and torque traces and test results fused per body. Two paint dirt defects localised to booth B-2 zone 3 before the humidity trim took effect; both routed to spot repair, none escaped to final.

  10. 10 eol.release SUCCEEDED 2 m 05 s

    EOL-and-Calibrate · End of line proved alignment, ADAS calibration, leak, brake, roll and functional tests on every vehicle; two ADAS retests sequenced inside takt. Shift 1 released with as-built records, approvals and dispositions written for the quality lead.

Tool calls · scenario

The agent shows its work

Every tool invocation, argument and result is written to an append-only, human-readable log, and every reasoning step is expandable. Nothing about a run is hidden from the plant.

tool-call stream · run_41a9c2
  1. 06:00:02mes.read_sequence({ plant: "BIW-2", shift: 1, program: "EV-CUV" })
  2. 06:00:03ok 412 bodies · 4 variants · weld set W-rev 7 · torque specs read-only
  3. 06:00:04twin.simulate({ candidates: 18, horizon: "1 shift" })
  4. 06:01:44ok best #6 · geometry inside targets · expulsion risk 0.06 · takt 61 s
  5. 06:01:45policy.evaluate({ candidate: 6, autonomy: "L2+" })
  6. 06:01:45ok 6 writes permitted · weld_schedule requires human approval · torque_spec locked
  7. 06:01:46blank.set_feed({ press: "P-3", delta: "+0.4 mm", lube: "+3%" })
  8. 06:02:30ok springback risk 0.42 → 0.11 · panel dimension in window
  9. 06:02:31approval.request({ action: "weld_schedule", robot: "W-14", current: "-2%", hold: "+20 ms" })
  10. 06:14:52ok approved by body-shop launch engineer · logged
  11. 06:14:53weld.apply_schedule({ robot: "W-14", rev: "7b" })
  12. 06:48:10ok 40 bodies in window · expulsion risk 0.31 → 0.06
  13. 06:48:11frame.set_offset({ station: "FS-1", datum: "B-pillar L", delta: "-0.3 mm" })
  14. 07:12:44ok 25 bodies inside targets · gap-and-flush confirmed
  15. 07:12:45booth.set_env({ booth: "B-2", humidity: "-2 pt", airflow: "rebalance" })
  16. 07:40:02precursor: dirt risk 0.58 · booth B-2 zone 3 · dark colour block
  17. 07:40:03ok 2 defects localised · routed to spot repair · 0 escaped
  18. 08:05:19unit.hold({ pack: "PK-1182", fastener: 7, reason: "torque trace off curve" })
  19. 08:05:19ok held at marriage · routed to rework · spec untouched
  20. 08:05:20sensors.fuse({ cams: 24, traces: true, tests: true })
  21. 13:40:00retest.sequence({ vehicles: 2, test: "ADAS calibration" })
  22. 13:52:31ok 2 retests passed inside takt
  23. 13:58:00mes.log_vehicle({ shift: 1, records: "as-built" })
  24. 14:00:05ok scenario complete · 10 steps · 0 escapes · shift released

Reasoning trace

Plan, thought, action, observation, exactly as the orchestrator would record it.

GoalRun shift 1 on plant BIW-2 inside the qualified envelopes, hol…

Run shift 1 on plant BIW-2 inside the qualified envelopes, hold body geometry at the framing station, keep expulsion and paint defects from escaping, hold every torque to specification and prove every vehicle at end of line.

PlanSimulate weld-sequence, framing and booth candidates on the tw…

Simulate weld-sequence, framing and booth candidates on the twin first. Lead with stamping so panels arrive in dimension, then propose the weld schedule and hold it for a human, then correct framing inside the envelope, then set the booth ahead of the colour block. Fuse inspection continuously. Never touch a torque specification or a test verdict.

ThoughtThe standing weld schedule on W-14 runs current high enough to…

The standing weld schedule on W-14 runs current high enough to guarantee the joint on the thickest stack. With the new coil lot and panel dimension held at P-3, the twin predicts the same joint quality at 2 percent lower current with a 20 ms hold, and lower expulsion, because the panels arrive flatter.

Actiontwin.simulate(candidates=18) returns #6: blank feed +0.4 mm on…

twin.simulate(candidates=18) returns #6: blank feed +0.4 mm on P-3, weld current -2 percent and +20 ms hold on W-14, framing offset -0.3 mm at FS-1, booth B-2 humidity -2 points for the dark block.

ObservationCandidate #6 predicts geometry inside targets, expulsion risk …

Candidate #6 predicts geometry inside targets, expulsion risk 0.06, a lower dirt map and takt at 61 seconds. Three candidates scored better on takt but pushed predicted B-pillar variation past the tolerance edge and were discarded.

ActionExecute #6: six bounded writes permitted on stamping, framing,…

Execute #6: six bounded writes permitted on stamping, framing, booth, routing and sequencing; the weld-schedule write routed to the body-shop launch engineer; torque specifications and test limits locked.

ObservationDirt precursor in booth B-2 zone 3 at 07:40:02 before the humi…

Dirt precursor in booth B-2 zone 3 at 07:40:02 before the humidity trim took effect. Two defects localised and routed to spot repair; none escaped. One pack held at marriage on a torque trace at 08:05:19.

OutcomeScenario complete. Geometry inside targets, no expulsion escap…

Scenario complete. Geometry inside targets, no expulsion escapes, paint defects caught in station, one pack reworked, two ADAS retests passed inside takt. Shift 1 released with full as-built records.

Where it pays

Four loops, four metrics

Chassira is not a dashboard. Each agent closes a loop a plant already measures in rework per body, repaint rate, faults escaping to end of line and downtime minutes. The tables show what each loop watches and what it is allowed to move.

Body shop

Catch the weld and the geometry before the body leaves framing

Servo-gun traces, seam vision and in-line measurement are fused at the cell into one estimate of joint quality and body geometry. Weld-and-Join proposes the schedule and sequence that hold crash-safety quality without geometry debt, the body-shop engineer approves, and Frame-and-Geometry corrects the framing station inside its envelope.

  • Joint quality scored per weld, not per destructive sample
  • Weld-schedule changes supervised by a named engineer
  • Framing corrections inside the qualified envelope, logged per body
agent.weld_join SUCCEEDED
Catch the weld and the geometry before the body leaves framing: signals watched and setpoints moved
SignalWatchesMoves
Weld current and forceServo-gun trace per jointSchedule proposal, under approval
ExpulsionTrace and seam visionCurrent and hold, under approval
Body dimensionIn-line measurementFraming offset inside the envelope
Paint shop

Set the booth before the defect, not the repaint after it

Booth temperature, humidity and airflow, film build and oven profiles are read per body and colour block. Paint-and-Finish predicts the defect map a body will carry and trims the booth inside the qualified window ahead of it; paint-defect vision localises what still appears to zone and condition.

  • Defects predicted from booth and chemistry state
  • Booth environment moved inside the qualified window
  • Every defect localised to zone, robot and condition
agent.paint_finish SUCCEEDED
Set the booth before the defect, not the repaint after it: signals watched and setpoints moved
SignalWatchesMoves
Booth environmentTemperature, humidity, airflow sensorsSetpoints inside the window
Film buildFilm-build gaugesFlash and cure profile
Dirt, runs, orange peelPaint-defect visionZone routing, spot-repair request
Pack and general assembly

Hold the unit before the torque fault leaves the station

Torque-to-yield traces, cell-to-pack joining signals, fill volumes and glazing vision are scored per fastener and per vehicle. Powertrain-and-Battery and Trim-and-Fasten hold and route units before a fault reaches end of line. Torque specifications and joint parameters are never written by an agent.

  • Every trace scored against the specification curve
  • Holds and routing, not parameter changes
  • Specifications locked read-only in the policy engine
agent.powertrain_battery SUCCEEDED
Hold the unit before the torque fault leaves the station: signals watched and setpoints moved
SignalWatchesMoves
Torque to yieldTool trace per fastenerUnit hold and routing
Pack integrityJoining, coolant and HV testsHold, proposal to engineer
Fluid fillVolume and pressureFill setpoints inside the window
End of line and takt

Prove the vehicle and hold the line

End-of-line results are fused with the upstream build record to predict failures before the stand sees them, and retests are sequenced inside takt. Sequence-and-Flow prices every sequence and buffer move in minutes and rework and optimises feeding and routing with cuOpt against launch cadence.

  • Failures predicted from upstream build data
  • Test verdicts and limits never written by an agent
  • Sequencing and buffers optimised, written inside agreed limits
agent.eol_calibrate SUCCEEDED
Prove the vehicle and hold the line: signals watched and setpoints moved
SignalWatchesMoves
ADAS calibrationTest-stand resultRetest sequencing
Alignment, leak, brake, rollTest-stand resultsRework routing
Takt and buffersMES, AGV and AMR stateSequence and buffer targets
Autonomy

Four levels, set per agent and per tag

A car plant does not go from manual to unattended in one step. Chassira makes the level explicit, auditable and reversible at any time. The first release runs shadow mode, then assist mode, then bounded autonomy on low-risk loops. Weld schedules stay supervised until the joint family is qualified, and torque specifications and test verdicts are never written by an agent.

Autonomy levels and the human role at each
LevelWhat the agent doesWhat the human doesWhere it sits in a pilot
L1 · ShadowReads weld, metrology, vision, torque, test, robot and MES signals; predicts and recommends; writes nothingRuns the line as today; compares predictions to audit and engineer outcomesDesign partners start here; the baseline is measured from the plant's own records
L2 · AssistProposes weld, framing, paint, routing, holding and sequencing moves with evidence, confidence, envelope and rollback pathApproves each action in the review consoleAssist mode: accuracy and ROI proven against the signed baseline
L3 · BoundedExecutes pre-approved low-risk actions: booth environment, framing offsets, blank feed and lubrication, routing, holds, sequencing, inside PLC and safety limits and the qualified envelopeApproves weld-schedule changes, torque-related decisions and vehicle releaseGraduated autonomy, after audited accuracy and ROI
L4 · ScaledSupervised weld-schedule adaptation for qualified joint families, across lines and plantsSets the envelope; reviews the shift record and evaluation resultsPlanned; after golden-dataset evaluation, twin validation and quality sign-off. Torque specifications and test verdicts never leave human hands
Accelerated computing

Physical AI, at the line

A spot weld lasts a fraction of a second and a body passes a station every minute. Perception has to be local, deterministic and fast, so Chassira runs GPU inference at the plant edge and keeps training, simulation and optimisation in the cloud or on-prem.

Jetson Orin · DeepStream · Holoscan · TensorRT

Edge perception

8 to 32 cameras per process area at 15 to 60 FPS, plus torque, dimensional, thermal, robot and paint-instrument streams fused at the cell. Weld and gap alerts under 50 ms and paint or dimensional prompts under 150 ms are the design targets. Jetson Thor is planned for higher density.

Triton · NIM

Model serving

Weld-defect, geometry-risk, paint-risk, torque and battery, and takt-risk models served at the plant edge with versioned rollback, routed by latency, tenant and cost, with canary rollout by line.

DGX or HGX · NeMo

Training

Weld, paint and gap vision, dimensional models, NeMo IATF and spec reasoning and GPU-accelerated stamping, springback and weld-geometry FEA surrogates. 150 to 600 GPU-hours per plant during onboarding, then monthly retraining from engineer corrections. Dedicated capacity is planned.

Omniverse · OVX

Plant twin

Body framing, weld sequence, robot reach, paint flow and line balance simulated before the shift. The pattern is production proven at BMW and Mercedes-Benz, per the architecture; Chassira's twin and OVX capacity are planned.

Cosmos · Omniverse Replicator

Synthetic data

Rare weld defects, paint failures, geometry-drift modes, occluded joints and misbuild cases generated and validated against real distributions before promotion. 50,000 to 250,000 variants per program is the design target. Planned.

cuOpt

Optimisation

Line sequencing and JIS feeding, AGV routing, takt, line balancing, buffers and retest sequencing.

Isaac · Isaac ROS

Robot cells and AMRs

Robotic weld, paint, assembly and inspection cells and AGV and AMR line-feed autonomy, with skills validated in simulation before a cell runs them.

RAPIDS

GPU ETL

Telemetry ETL across weld and press parameters, measurements, paint readings, torque traces, battery and ADAS results, non-conformance and takt history for retraining and benchmarks.

NeMo Guardrails · NVIDIA AI Enterprise

Policy and deployment

Spec, IATF, functional-safety, cyber and human-approval policy enforced before any write; supportable on-prem or plant-edge deployment for regulated OEM plants.

Guardrails

An agent near a crash-safety joint needs a leash

Chassira writes to production equipment. Every capability is scoped, every write is policy-checked against the qualified envelope, safety-critical parameters are locked, and every action is written to an append-only audit log the plant owns.

  • Bounded action space. Each agent writes only to an explicit tag allow-list, inside per-tag rate and magnitude limits and the qualified process envelope for the joint family, colour block or vehicle program.
  • Policy engine before every write. Autonomy level, shift, program, interlock state and operator presence are evaluated before a setpoint moves. NeMo Guardrails enforces spec, IATF, functional-safety, cyber and human-approval policy before any action writes back to robots, MES, QA or work instructions.
  • Safety-critical parameters locked. Weld schedules wait for a named body-shop engineer until the joint family is qualified. Torque specifications, battery-joint parameters and end-of-line test limits and verdicts are read-only to every agent, always.
  • Immutable audit log. Append-only and exportable. Every action records source evidence, the approved envelope, confidence, estimated quality, rework, downtime and warranty impact, rollback path, approver and vehicle scope.
  • Hard fallback. Loss of the edge node, the network or a model returns control to the press, robot, booth or MES controller's last known-good state. Safety-rated PLCs and interlocks are never in Chassira's path.
  • Tenant and program isolation. Vehicle designs, control plans, specs, models and memory never cross an OEM boundary. On-prem and plant-edge deployment are available for regulated plants.

Compliance posture

Compliance and certification status
ItemScopeStatus
SOC 2 Type ICloud control plane QUEUED Planned, first 6 months, with an IATF and functional-safety-aware review
SOC 2 Type IICloud control plane QUEUED Planned, 6 to 12 months
SSO and RBACConsole and approvals QUEUED Planned, 6 to 12 months
IATF 16949 and APQP assurance packagesDisposition and traceability evidence QUEUED Planned, 6 to 12 months; not a certification claim
ISO 26262-aware controlFunctional-safety requirements cited in reasoning and gates RUNNING In the design; not a certification claim
Standards-cited reasoningIATF 16949, APQP and PPAP, torque specs, recall procedures RUNNING In the design, every answer cites its source
Per-tenant and program isolationDesigns, control plans, models, memory RUNNING In the design from day one
On-prem and plant-edge deploymentRegulated OEM plants RUNNING Design option

Read the security overview

FAQ

Straight answers

The questions plant managers, launch engineers and quality leads ask in the first meeting.

Yes, but only within an explicit tag allow-list with per-tag rate and magnitude limits, inside the qualified envelope, and only at the autonomy level your plant has set. Design partners start in shadow mode, where Chassira writes nothing. Weld-schedule changes wait for a named body-shop engineer, and torque specifications, battery-joint parameters and end-of-line test limits and verdicts are read-only to every agent, always.

Get started

See the features on one process

Start with one process and one measurable baseline. A paid pilot on body-shop weld and gap-and-flush vision, paint-defect detection and film-build control, or torque and battery-joint conformance shows the number before you commit further.