Scenarios

Three walk-throughs. All of them labelled scenarios.

Chassira has no customer results yet, so this page does not pretend to. Each scenario describes a hypothetical line, what the agent would do at each autonomy level, and the metric table the pilot would fill in. When a design partner signs, the first real case study replaces the first scenario.

3 scenarios0 customer results claimedMetric tables, not outcomes

run_41a9c2 · agent graph · plant BIW-2 · scenario 10 nodes · 1 approval gate
01 · orchestrator ingest.shift ✓ SUCCEEDED 02 · vehicle_line twin.simulate ✓ SUCCEEDED 03 · stamp_form stamp.form ✓ SUCCEEDED 04 · orchestrator approve.human ◆ APPROVAL 05 · weld_join weld.join ✓ SUCCEEDED 06 · frame_geometry frame.geometry ✓ SUCCEEDED 07 · paint_finish paint.finish ✓ SUCCEEDED 08 · powertrain_battery marriage.torque ✓ SUCCEEDED 09 · quality_anomaly inspect.fuse ✓ SUCCEEDED 10 · eol_calibrate eol.release ✓ SUCCEEDED

Illustrative scenario: Plant BIW-2 · EV crossover body shop to end of line · shift 1, one approval gate

Scenario 01 · Body shop

Weld-defect and gap-and-flush vision on an EV crossover body shop

A hypothetical body-in-white line: 40-plus joining robots, servo-gun spot welding, laser seams on the roof, self-pierce rivets on the aluminium closures, structural adhesive, two framing stations with in-line metrology. Today joint quality is judged by sampled teardown and geometry by audit.

What the agent would do

  1. Shadow mode. Weld-and-Join scores every joint from current, force and expulsion traces and seam vision; Frame-and-Geometry reads in-line measurement and gap-and-flush images and predicts where variation is heading.
  2. Assist mode. Weld-and-Join proposes schedule and sequence changes ranked on the twin and the body-shop launch engineer approves each; Frame-and-Geometry proposes framing offsets.
  3. Bounded autonomy. framing offsets inside the qualified envelope execute automatically; every weld-schedule change stays with the engineer.
Weld and join with Frame and geometryscenario
What the pilot would record
MetricHowResult
Weld rework per bodyrework events by joint and station, before and duringto be measured
Expulsion eventsper shift, by robotto be measured
Bodies out of toleranceper shift, by datumto be measured
Gap-and-flush reworkper body at finalto be measured

No result is claimed. The metric table is what the pilot would record.

Scenario 02 · Paint shop

Paint-defect detection and film-build control on a two-booth paint shop

A hypothetical paint shop: pretreat and e-coat, sealer, two colour booths, flash and cure ovens, a manual inspection deck. Today defects are found at the deck and fixed by spot repair or repaint, and the booth runs a fixed recipe per colour.

What the agent would do

  1. Shadow mode. Paint-and-Finish reads booth environment, film build and oven profiles per body and colour block and predicts the defect map; paint-defect vision on the deck localises what appears to zone and condition.
  2. Assist mode. Paint-and-Finish proposes booth humidity, airflow and flash adjustments ahead of each colour block; the paint engineer approves.
  3. Bounded autonomy. booth environment moves inside the qualified window; recipe and chemistry changes stay with the engineer.
Paint and finish with Quality and anomalyscenario
What the pilot would record
MetricHowResult
Repaint ratebodies repainted per shift, before and duringto be measured
Paint defects per bodyby type: dirt, runs, orange peel, film buildto be measured
Film build in windowshare of bodies, per colourto be measured
Detection accuracyvision against the inspection deckto be measured

No result is claimed. The metric table is what the pilot would record.

Scenario 03 · Pack and marriage

Torque and battery-joint conformance on a new battery-pack line

A hypothetical cell-to-pack line standing up for a new EV program: cell-to-pack joining, coolant and high-voltage integrity tests, torque-to-yield fastening at marriage. Today traces are recorded for traceability and faults are found at end of line or in the field.

What the agent would do

  1. Shadow mode. Powertrain-and-Battery scores every torque-to-yield trace against the specification curve and every joining and integrity signal per pack, and compares its calls with end-of-line results.
  2. Assist mode. the agent proposes holds and routing for units it predicts will fail; the process engineer decides. Torque specifications and joint parameters are never proposed for change.
  3. Bounded autonomy. holds and routing execute automatically inside agreed limits; everything about the specification stays human.
Powertrain and batteryscenario
What the pilot would record
MetricHowResult
Faults caught before end of lineper shift, by fastener and jointto be measured
Marriage reworkunits per shiftto be measured
Escapes to end of line and fieldper program, before and duringto be measured
Record completenessshare of packs with a full trace recordto be measured

No result is claimed. The metric table is what the pilot would record.

Run timeline · scenario

The reference scenario, step by step

Every Chassira run is an ordered, inspectable sequence. This is run_41a9c2 on Plant BIW-2 · EV crossover body shop to end of line · shift 1. Scenario completes in 10 steps with one approval gate. Weld schedule change on robot W-14 approved by the body-shop launch engineer, framing offset held inside the envelope, booth humidity trimmed before the predicted dirt defects appeared, one pack held at marriage on a torque trace, and the shift released with full as-built records.

run_41a9c2 Plant BIW-2 · EV crossover body shop to end of line · shift 1 illustrative scenario SUCCEEDED
  1. 01 ingest.shift SUCCEEDED 0.8 s

    Plant Orchestrator · Pulled the shift build sequence, program control plan and qualified envelopes from MES: 412 bodies, four trim variants, weld schedule set W-rev 7, framing targets per station, paint colour blocks, torque specifications. Locked every safety-critical parameter as read-only.

  2. 02 twin.simulate SUCCEEDED 1 m 40 s

    Vehicle-and-Line Twin · Simulated 18 candidate weld-sequence, framing-offset and booth-window combinations on the plant twin, ranked on predicted body geometry, expulsion risk at robot W-14, paint defect map and takt against launch cadence.

  3. 03 stamp.form SUCCEEDED continuous

    Stamp-and-Form · Blank feed on press line P-3 adjusted by 0.4 mm and lubricant dose raised 3 percent for the new coil lot as springback risk on the rear door inner climbed. Panel dimension held inside the window; genealogy handed to framing.

  4. 04 approve.human APPROVAL 3 m 12 s

    Plant Orchestrator · Candidate #6 lowers weld current 2 percent and adds 20 ms hold on robot W-14 to cut predicted expulsion. Weld schedules are crash-safety critical and stay with a human, so the change was held for the body-shop launch engineer and approved at 06:14:52.

  5. 05 weld.join SUCCEEDED continuous

    Weld-and-Join · Approved schedule 7b applied on W-14. Current and force traces confirmed inside the window on the first 40 bodies; predicted expulsion risk fell from 0.31 to 0.06 and no geometry debt was introduced at the adjacent seams.

  6. 06 frame.geometry SUCCEEDED continuous

    Frame-and-Geometry · Framing station FS-1 offset corrected by 0.3 mm on the left B-pillar datum inside the qualified envelope as in-line measurement trended toward the tolerance edge. Gap-and-flush vision confirmed the correction on the next 25 bodies.

  7. 07 paint.finish SUCCEEDED continuous

    Paint-and-Finish · Booth B-2 humidity trimmed 2 points and airflow rebalanced for the dark-colour block as the defect model predicted dirt on horizontal panels. Film build held inside the window on the first colour block.

  8. 08 marriage.torque SUCCEEDED continuous

    Powertrain-and-Battery · Pack PK-1182 held at marriage after a torque-to-yield trace on fastener 7 fell outside the specification curve. Routed to rework with the trace attached; torque specification untouched, as always.

  9. 09 inspect.fuse SUCCEEDED continuous

    Quality-and-Anomaly · Gap-and-flush and paint-defect cameras, weld and torque traces and test results fused per body. Two paint dirt defects localised to booth B-2 zone 3 before the humidity trim took effect; both routed to spot repair, none escaped to final.

  10. 10 eol.release SUCCEEDED 2 m 05 s

    EOL-and-Calibrate · End of line proved alignment, ADAS calibration, leak, brake, roll and functional tests on every vehicle; two ADAS retests sequenced inside takt. Shift 1 released with as-built records, approvals and dispositions written for the quality lead.

Tool calls · scenario

The agent shows its work

Every tool invocation, argument and result is written to an append-only, human-readable log, and every reasoning step is expandable. Nothing about a run is hidden from the plant.

tool-call stream · run_41a9c2
  1. 06:00:02mes.read_sequence({ plant: "BIW-2", shift: 1, program: "EV-CUV" })
  2. 06:00:03ok 412 bodies · 4 variants · weld set W-rev 7 · torque specs read-only
  3. 06:00:04twin.simulate({ candidates: 18, horizon: "1 shift" })
  4. 06:01:44ok best #6 · geometry inside targets · expulsion risk 0.06 · takt 61 s
  5. 06:01:45policy.evaluate({ candidate: 6, autonomy: "L2+" })
  6. 06:01:45ok 6 writes permitted · weld_schedule requires human approval · torque_spec locked
  7. 06:01:46blank.set_feed({ press: "P-3", delta: "+0.4 mm", lube: "+3%" })
  8. 06:02:30ok springback risk 0.42 → 0.11 · panel dimension in window
  9. 06:02:31approval.request({ action: "weld_schedule", robot: "W-14", current: "-2%", hold: "+20 ms" })
  10. 06:14:52ok approved by body-shop launch engineer · logged
  11. 06:14:53weld.apply_schedule({ robot: "W-14", rev: "7b" })
  12. 06:48:10ok 40 bodies in window · expulsion risk 0.31 → 0.06
  13. 06:48:11frame.set_offset({ station: "FS-1", datum: "B-pillar L", delta: "-0.3 mm" })
  14. 07:12:44ok 25 bodies inside targets · gap-and-flush confirmed
  15. 07:12:45booth.set_env({ booth: "B-2", humidity: "-2 pt", airflow: "rebalance" })
  16. 07:40:02precursor: dirt risk 0.58 · booth B-2 zone 3 · dark colour block
  17. 07:40:03ok 2 defects localised · routed to spot repair · 0 escaped
  18. 08:05:19unit.hold({ pack: "PK-1182", fastener: 7, reason: "torque trace off curve" })
  19. 08:05:19ok held at marriage · routed to rework · spec untouched
  20. 08:05:20sensors.fuse({ cams: 24, traces: true, tests: true })
  21. 13:40:00retest.sequence({ vehicles: 2, test: "ADAS calibration" })
  22. 13:52:31ok 2 retests passed inside takt
  23. 13:58:00mes.log_vehicle({ shift: 1, records: "as-built" })
  24. 14:00:05ok scenario complete · 10 steps · 0 escapes · shift released

Reasoning trace

Plan, thought, action, observation, exactly as the orchestrator would record it.

GoalRun shift 1 on plant BIW-2 inside the qualified envelopes, hol…

Run shift 1 on plant BIW-2 inside the qualified envelopes, hold body geometry at the framing station, keep expulsion and paint defects from escaping, hold every torque to specification and prove every vehicle at end of line.

PlanSimulate weld-sequence, framing and booth candidates on the tw…

Simulate weld-sequence, framing and booth candidates on the twin first. Lead with stamping so panels arrive in dimension, then propose the weld schedule and hold it for a human, then correct framing inside the envelope, then set the booth ahead of the colour block. Fuse inspection continuously. Never touch a torque specification or a test verdict.

ThoughtThe standing weld schedule on W-14 runs current high enough to…

The standing weld schedule on W-14 runs current high enough to guarantee the joint on the thickest stack. With the new coil lot and panel dimension held at P-3, the twin predicts the same joint quality at 2 percent lower current with a 20 ms hold, and lower expulsion, because the panels arrive flatter.

Actiontwin.simulate(candidates=18) returns #6: blank feed +0.4 mm on…

twin.simulate(candidates=18) returns #6: blank feed +0.4 mm on P-3, weld current -2 percent and +20 ms hold on W-14, framing offset -0.3 mm at FS-1, booth B-2 humidity -2 points for the dark block.

ObservationCandidate #6 predicts geometry inside targets, expulsion risk …

Candidate #6 predicts geometry inside targets, expulsion risk 0.06, a lower dirt map and takt at 61 seconds. Three candidates scored better on takt but pushed predicted B-pillar variation past the tolerance edge and were discarded.

ActionExecute #6: six bounded writes permitted on stamping, framing,…

Execute #6: six bounded writes permitted on stamping, framing, booth, routing and sequencing; the weld-schedule write routed to the body-shop launch engineer; torque specifications and test limits locked.

ObservationDirt precursor in booth B-2 zone 3 at 07:40:02 before the humi…

Dirt precursor in booth B-2 zone 3 at 07:40:02 before the humidity trim took effect. Two defects localised and routed to spot repair; none escaped. One pack held at marriage on a torque trace at 08:05:19.

OutcomeScenario complete. Geometry inside targets, no expulsion escap…

Scenario complete. Geometry inside targets, no expulsion escapes, paint defects caught in station, one pack reworked, two ADAS retests passed inside takt. Shift 1 released with full as-built records.

Autonomy

Four levels, set per agent and per tag

A car plant does not go from manual to unattended in one step. Chassira makes the level explicit, auditable and reversible at any time. The first release runs shadow mode, then assist mode, then bounded autonomy on low-risk loops. Weld schedules stay supervised until the joint family is qualified, and torque specifications and test verdicts are never written by an agent.

Autonomy levels and the human role at each
LevelWhat the agent doesWhat the human doesWhere it sits in a pilot
L1 · ShadowReads weld, metrology, vision, torque, test, robot and MES signals; predicts and recommends; writes nothingRuns the line as today; compares predictions to audit and engineer outcomesDesign partners start here; the baseline is measured from the plant's own records
L2 · AssistProposes weld, framing, paint, routing, holding and sequencing moves with evidence, confidence, envelope and rollback pathApproves each action in the review consoleAssist mode: accuracy and ROI proven against the signed baseline
L3 · BoundedExecutes pre-approved low-risk actions: booth environment, framing offsets, blank feed and lubrication, routing, holds, sequencing, inside PLC and safety limits and the qualified envelopeApproves weld-schedule changes, torque-related decisions and vehicle releaseGraduated autonomy, after audited accuracy and ROI
L4 · ScaledSupervised weld-schedule adaptation for qualified joint families, across lines and plantsSets the envelope; reviews the shift record and evaluation resultsPlanned; after golden-dataset evaluation, twin validation and quality sign-off. Torque specifications and test verdicts never leave human hands
FAQ

Straight answers

The questions plant managers, launch engineers and quality leads ask in the first meeting.

Yes, but only within an explicit tag allow-list with per-tag rate and magnitude limits, inside the qualified envelope, and only at the autonomy level your plant has set. Design partners start in shadow mode, where Chassira writes nothing. Weld-schedule changes wait for a named body-shop engineer, and torque specifications, battery-joint parameters and end-of-line test limits and verdicts are read-only to every agent, always.

Get started

Make the first scenario real

Start with one process and one measurable baseline. A paid pilot on body-shop weld and gap-and-flush vision, paint-defect detection and film-build control, or torque and battery-joint conformance shows the number before you commit further.